ETF Motorized Valve Actuator

ETF series motorized valve is applicable to air conditioning system, heating system or building automation system. According to the floating-point or proportional signal (DC 0/2~10V or DC 4/0~20- mA) from PLC, DDC and
thermostat, the opening of the valve is adjusted to control the flow of the medium in the pipeline and to meet the accurate control of the flow, pressure, and temperature.

Download

Features

Rated Torsion: ETF..10 1000N Rated Stroke:22mm

                                    ETF...15 1500N Rated Stroke:22mm

                                    ETF...18 1800N Rated Stroke: 25mm

                                    ETF..30 3000N Rated Stroke: 50mm

Control Mode: 3 points floating/ Proportional control

3 points floating type: 24VAC/220VAC

Proportional control type: 24VAC/220VAC
0(2)-10VDC control Signal
0(2)-10VDC feedback
4(0)-20mA control signal (Positioner impedance=2502)
4(0)-20mA feedback (Carrying capacity < 5000)
Proportional control type has self- adaptive function, the zero position and full position of valves with diferent diameters
and different strokes could be set by one key.
Proportional control type:remote auto control mode and local control mode selectable by DIP switch on proportional
controltype
Selectable fully open, fully closed or hold when control signal missing by DIP switch on proportional control type.
Optional Function:

Extreme position passive point
2k or 10k potentiometer feedback
Manually setting zero and full points.
Control accuracy: basic error 3%, dead band I3%.
Ambient conditions:-10 C-50° C, 90% RH no condensation, non-corrosive gas, mechanical vibration is less than 1g. IP54

Models

Model Torsion Power Supply Power Consumption Signal Speed
(s/mm 50Hz)
Control Signal Feedback
ETF-Y2-10K 1000N 24VAC 6.7 VA 0(2)...10VDC or 4(0)...20mA 0(2)...10VDC or 4(0)...20mA 3.9
ETF-X2-10K 1000N 24VAC 5.5 VA 3 points floating - 3.9
ETF-X1-10K 1000N 220VAC 5.5 VA 3 points floating - 3.9
ETF-Y2-15K 1500N 24VAC 6.7 VA 0(2)...10VDC or 4(0)...20mA 0(2)...10VDC or 4(0)...20mA 3.9
ETF-X2-15K 1500N 24VAC 5.5 VA 3 points floating - 3.9
ETF-X1-15K 1500N 220VAC 5.5 VA 3 points floating - 3.9
ETF-Y2-18/30K 1800N/3000N 24VAC 18 VA 0(2)...10VDC or 4(0)...20mA 0(2)...10VDC or 4(0)...20mA 3.1
ETF-X2-18/30K 1800N/3000N 24VAC 16 VA 3 points floating AC24V 3.1
ETF-Y1-18/30K 1800N/3000N 220VAC 18 VA 0(2)...10VDC or 4(0)...20mA 0(2)...10VDC or 4(0)...20mA 3.1
ETF-X1-18/30K 1800N/3000N 220VAC 16 VA 3 points floating AC220V 3.1

INSTALLATION DIAGRAM

APPLICATION

RELATED NEWS

News Best Thermostats for Hydronic Radiant Floor Heating: A Distributor Guide
On September 10, 2026
Best Thermostats for Hydronic Radiant Floor Heating: A Distributor Guide
Thermostat selection is easy to get wrong in hydronic radiant floor heating. A thermostat may look suitable on the product page but still fail to match the heat…
Learn More
News Where Can Buy Motorized Balancing Valves for Commercial HVAC in Bulk?
On August 24, 2026
Where Can Buy Motorized Balancing Valves for Commercial HVAC in Bulk?
Choosing the right motorized balancing valves for commercial HVAC requires more than comparing unit prices. This article explains key specifications, valve types, actuator options, control signals, application scenarios,…
Learn More
News Which duct air flow sensors support 4 to 20 mA output for building automation?
On August 15, 2026
Which duct air flow sensors support 4 to 20 mA output for building automation?
Learn how duct air flow sensors with 4 to 20 mA output support HVAC building automation, including selection, compatibility, installation, and maintenance.
Learn More

We value your privacy

We use cookies to enhance your browsing experience, serve personalised ads or content, and analyse our traffic. By clicking "Accept All", you consent to our use of cookies.