HL-SO series outdoor temperature and humidity sensor

HL-SO series outdoor sensors are used for outdoor temperature and humidity measurement in building automation systems. They can provide a variety
of temperature measurement ranges, as well as NTC, platinum resistance, voltage, and current signal outputs to adapt to the different requirements of various control systems.
Download

The HL-SO Series Outdoor Temperature and Humidity Sensor is designed for reliable outdoor and environmental monitoring in HVAC, building automation, energy management, and other temperature and humidity measurement applications.

The series provides multiple sensing and signal output options, including NTC10K, NTC20K, PT1000, 0–10V, and 4–20mA, allowing users to select the appropriate configuration for different controllers and building automation systems.

Selected models combine temperature and relative humidity measurement in one device, while different output configurations support flexible integration with HVAC controllers, DDC systems, monitoring platforms, and other automation equipment.

With a wide operating environment and IP65 protective level, the HL-SO Series is suitable for applications where sensors need to operate reliably in outdoor or demanding environmental conditions.

 

Outdoor Temperature and Humidity Monitoring

 

Temperature and relative humidity are important environmental parameters for HVAC control, building automation, energy management, and equipment protection.

The HL-SO Series provides different combinations of temperature and humidity sensing to meet various application requirements. Depending on the model, the sensor can provide:

  • Temperature measurement only
  • Temperature and relative humidity measurement
  • Passive temperature signals such as NTC10K, NTC20K, and PT1000
  • Analog temperature outputs such as 0–10V and 4–20mA
  • Analog relative humidity outputs
  • Combined temperature and humidity outputs

This flexible model structure allows the sensor to be matched with different controllers and signal acquisition systems.

 

Relative Humidity Measurement

 

Selected HL-SO Series models combine temperature and relative humidity sensing in the same housing.

The humidity measurement range can cover 0–100% RH depending on the selected model, while humidity accuracy varies according to the specific configuration.

The sensor can therefore provide environmental information required for:

  • HVAC monitoring
  • Indoor and outdoor climate monitoring
  • Building automation
  • Air-conditioning control
  • Humidity management
  • Equipment environment monitoring
  • Energy management systems

Professional temperature and humidity sensors commonly combine temperature and relative humidity measurement in a single device. R. M. Young, for example, offers combined probes using a humidity sensing element together with a precision temperature sensor, with analog output options including 0–1 VDC and 4–20mA.

 

Multiple Analog Signal Outputs

 

A major feature of the HL-SO Series is its range of signal output configurations.

This allows the sensor to integrate with different types of HVAC controllers and building automation equipment.

For example, a 4–20mA output can be connected to a controller with a current input, while a 0–10V output can be connected to a compatible analog voltage input.

The same principle is widely used across professional environmental sensors. R. M. Young provides temperature and humidity probes with both voltage and current output configurations, while Setra's humidity sensors also offer 4–20mA and 0–10V output options.

 

IP65 Protection for Outdoor Applications

 

The HL-SO Series features an IP65 protective level, making it suitable for applications where the sensor may be exposed to dust and water spray.

The outdoor sensor design is intended for environmental monitoring applications where reliable measurement is required under changing temperature and humidity conditions.

When installing an outdoor temperature and humidity sensor, the installation position should be selected carefully to avoid direct heat sources and conditions that may affect measurement accuracy.

For professional outdoor environmental measurement, sensor protection from solar radiation and precipitation is also an important consideration. R. M. Young uses dedicated multi-plate and aspirated radiation shields to reduce measurement errors caused by solar radiation and precipitation.

For the HL-SO Series, the final installation method should follow the product's installation requirements and the actual project environment.

 

Wide Operating Environment

 

The HL-SO Series is designed to operate across a wide environmental range:

  • Working temperature: -40–80°C
  • Working humidity: 5–95% RH
  • Humidity condition: No condensation
  • Protection level: IP65

This operating range allows the series to be used in a variety of outdoor and environmental monitoring applications.

 

HVAC and Building Automation Integration

 

Outdoor temperature and humidity information can be used as input data for HVAC and building automation systems.

A typical building automation architecture may include:

Outdoor Sensor → DDC Controller → HVAC Equipment → Building Management System

The HL-SO Series can provide outdoor environmental data to compatible controllers, which can then use the measured values for HVAC control, monitoring, scheduling, or energy management.

HaiLin Controls provides a broader HVAC automation portfolio covering thermostats, sensors, DDC controllers, gateways, valves, and building management platforms, allowing environmental sensors to be integrated into complete building automation solutions.

 

Applications

 

Building Automation

 

The HL-SO Series can provide outdoor temperature and humidity data for building automation systems.

The measured values can be used by controllers and management platforms to monitor environmental conditions and support HVAC operation.

 

HVAC Systems

 

Outdoor temperature is an important parameter in many HVAC control strategies. Humidity information can also support environmental monitoring and air-conditioning management.

The HL-SO Series can be connected to compatible HVAC controllers through NTC, RTD, 0–10V, or 4–20mA signals depending on the selected model.

 

Commercial Buildings

 

The sensor can be used in office buildings, commercial complexes, hotels, and other facilities where environmental conditions need to be monitored as part of HVAC or building management.

 

Industrial Facilities

 

Models with analog outputs such as 4–20mA can be used in industrial monitoring and control environments where standardized signal transmission is required.

 

Energy Management

 

Outdoor environmental information can be incorporated into HVAC energy management strategies. Controllers can use temperature and humidity data together with other building parameters to optimize system operation.

 

Environmental Monitoring

 

The combination of temperature and relative humidity measurement makes selected models suitable for general environmental monitoring applications.

 

Suitable for Different Control Architectures

 

The HL-SO Series can support different system architectures because of its multiple output configurations.

 

Passive Sensor Integration

 

Models using NTC10K, NTC20K, or PT1000 can be connected directly to compatible controllers designed for resistance-based temperature sensing.

 

Analog Voltage Integration

 

Models with 0–10V outputs can transmit temperature or humidity information to compatible analog inputs.

 

Analog Current Integration

 

Models with 4–20mA outputs can integrate with controllers and monitoring equipment using current-loop inputs.

This flexibility helps reduce the need for different sensor platforms across projects with different controller interfaces.

Specifications

Model Temp. measuring range Temp. Signal Output Temp. Accuracy Humidity Measuring Range Humidity Signal Output Humidity accuracy Working voltage Working temp.&humidity Protective level
HL-SOT3 -20~80℃ NTC10K ±0.3℃ (@25℃) DC15~35V -40~80℃ 5~95% RH (No condensation) IP65
HL-SOT7 NTC20K
HL-SOT5R4 0~10V
HL-SOT6R4 4~20ma
HL-SOT2H3 PT1000 ±0.2℃ (@0℃) 0~100%RH 4~20ma 20~90% RH ±3% RH 0~100% RH ±5% RH
HL-SOT3H3 NTC10K ±0.3℃ (@25℃) 4~20ma
HL-SOT7H2 NTC20K 0~10V
HL-SOT7H3 NTC20K 4~20ma
HL-SOT5R4H2 0~10V 0~10V
HL-SOT6R1H3 0~50℃ 4~20ma 4~20ma
HL-SOT6R4H3 -20~80℃ 4~20ma 4~20ma

Why Choose HaiLin Controls?

 

HaiLin Controls specializes in HVAC automation and building control products, providing a complete product portfolio that includes thermostats, sensors, controllers, gateways, valves, and building management systems.

This allows the HL-SO Series to be used not only as an independent outdoor environmental sensor, but also as part of a larger HVAC automation solution.

HaiLin's solutions cover different building environments and applications, including commercial buildings, hotels, healthcare facilities, public buildings, and other HVAC-controlled spaces.

The company also provides project-oriented technical and service support, helping customers with product selection, system integration, commissioning, and after-sales requirements.

 

Related HaiLin Controls Products

 

The HL-SO Series can be combined with other HaiLin Controls products to create a complete HVAC and building automation system.

  • Thermostats – Room-level heating and cooling control
  • Fan Coil Thermostats – FCU temperature and fan control
  • PI Control Thermostats – Precise temperature control with modulating valve output
  • Temperature Sensors – Temperature measurement for HVAC systems
  • Humidity Sensors – Relative humidity monitoring
  • DDC Controllers – HVAC and building automation control
  • Motorized Valves – Hydronic heating and cooling control
  • Gateways – Communication and system integration
  • Building Management Platforms – Centralized HVAC and energy management

 

Frequently Asked Questions

 

What is an outdoor temperature and humidity sensor?

 

An outdoor temperature and humidity sensor measures ambient temperature and relative humidity and sends the measured values to a compatible controller or monitoring system.

These measurements can be used for HVAC control, environmental monitoring, building automation, and energy management.

 

Does the HL-SO Series measure both temperature and humidity?

 

Selected models provide both temperature and relative humidity measurement. Other models are designed for temperature measurement only.

 

What is the humidity measuring range?

 

Selected humidity models provide a 0–100% RH measuring range. Accuracy varies according to the model and humidity range.

 

Is the HL-SO Series suitable for outdoor installation?

 

The series has models specified with an IP65 protective level and a working environment of -40–80°C and 5–95% RH without condensation.

The final installation location and method should follow the product's installation requirements.

 

Why is humidity measurement important for HVAC?

 

Relative humidity affects indoor comfort, air quality, condensation risk, and HVAC operation. Monitoring humidity alongside temperature provides more complete environmental information for building control systems.

 

Inquiry

 

Contact HaiLin Controls for outdoor temperature and humidity sensor selection, HVAC controller matching, building automation integration, OEM/ODM requirements, and project support.

Our technical team can help select the appropriate sensing element and output configuration according to the controller input, temperature range, humidity measurement requirements, installation environment, and application.

APPLICATION

RELATED NEWS

News Best Thermostats for Hydronic Radiant Floor Heating: A Distributor Guide
On September 10, 2026
Best Thermostats for Hydronic Radiant Floor Heating: A Distributor Guide
Thermostat selection is easy to get wrong in hydronic radiant floor heating. A thermostat may look suitable on the product page but still fail to match the heat…
Learn More
News Where Can Buy Motorized Balancing Valves for Commercial HVAC in Bulk?
On August 24, 2026
Where Can Buy Motorized Balancing Valves for Commercial HVAC in Bulk?
Choosing the right motorized balancing valves for commercial HVAC requires more than comparing unit prices. This article explains key specifications, valve types, actuator options, control signals, application scenarios,…
Learn More
News Which duct air flow sensors support 4 to 20 mA output for building automation?
On August 15, 2026
Which duct air flow sensors support 4 to 20 mA output for building automation?
Learn how duct air flow sensors with 4 to 20 mA output support HVAC building automation, including selection, compatibility, installation, and maintenance.
Learn More

We value your privacy

We use cookies to enhance your browsing experience, serve personalised ads or content, and analyse our traffic. By clicking "Accept All", you consent to our use of cookies.